Changes the error result from CMD_INVALID to CMD_FAILURE, since
CMD_INVALID indicates an unknown command or parser error and neither
occurs where CMD_INVALID was used.
Since the output config is no longer applied before creating the default
workspace, the layout for default workspaces on an output may not be
correct. Due to the ordering of calls in output_enable being changed in
several bug fix PRs, this just fixes the layout after the call to
apply_output_config.
When adding a container to the scratchpad, it was possible for focus to
be removed from the seat. This occurred when a single child was moved
from it's parent to the scratchpad due to the focus_inactive for the
parent being NULL. If the focus_inactive for the parent is NULL, the
focus_inactive for the workspace should be focused.
Adds the bar subcommand `gaps <amount>|<horizontal> <vertical>|<top>
<right> <bottom> <left>` to set gaps for swaybar. Due to restrictions on
margins for a layer_surface, only the sides that are anchored to an edge
of the screen can have gaps. Since there is support for per-side outer
gaps for workspaces, those should be able to be used instead for the
last side.
In `i3 4.16`, `i3-msg` can be used with the message type `subscribe`
and has the ability to monitor for responses until killed. This adds
support for both to swaymsg.
If the JSON array of event types is malformed or contains an invalid
event, sway will send a response with `success` set to `false`. If
swaymsg sees this, it will not display the failure and exit.
If the `subscribe` event is successful, swaymsg will wait for the first
response and display that instead of the success message. If
`-m/--monitor` is given, swaymsg will continue monitor for responses
until killed or a malformed response is received.
For the `subscribe` event, the responses will always be printed as JSON.
If `-r/--raw` is given, the JSON will not be pretty printed, which may
be preferred when monitoring due to there being multiple responses.
Example: `swaymsg -t SUBSCRIBE -m "['window']"`
Adds the function `config_add_swaynag_warning(char *fmt, ...)` so that
handlers can add warnings to the swaynag config log in a uniform way.
The formatting is identical to errors and include the line number, line,
and config path.
This also alters the background file access warning to use the function
and introduces a warning for duplicate bindings.
moving a container to a non-empty workspace will find a container to move
to in the destination workspace and call container_move_to_container,
which must not just skip floating containers
Like with cmd_bindsym and cmd_bindcode, the quotes should not be
stripped for cmd_mode. cmd_mode performs its own stripping for the mode
name and the only valid subcommands are cmd_bindsym and cmd_bindcode.
In `i3 4.16`, `i3-nagbar` introduces the flags `-B/--button-no-terminal`
to run the action directly instead of inside a terminal. This implements
the flags for swaynag for compatibility.
Since swaynag does not use an equivalent to `i3-sensible-terminal`, the
flags `-b/--button` only uses a terminal when the environment variable
`TERMINAL` is set, otherwise it acts the same as these new flags.
This matches i3's behavior of returning a list of results that contain
the result of each command that was executed. Additionally, the
`parse_error` attribute has been added to the IPC JSON reply.
Damage subsurfaces when they are destroyed. Since subsurfaces don't have an
unmap event we need to do that on destroy.
We also don't want to keep a sway_view_child when the wlr_subsurface has been
destroyed.
Fixes https://github.com/swaywm/sway/issues/3197
This patch allows IPC clients to receive window::move events
when containers are moved to scratchpad or when hidden containers
are shown via "scratchpad show" command.
This adds support for `i3 4.16`'s ability to set the title alignment.
The command is `title_align left|center|right`.
When the title is on the right, marks are moved to the left. Otherwise,
they are on the right.